Modular series 2019-01-22T13:59:06+08:00

Modular Series Current Transformers

Customized CTs are available upon request

Stability
Accuracy
Cost

Multiple Models To Choose

FDC-KXR-XXX-PTXX Combined Power Series

Dimensions in (mm)


A B C D E
100 46 70 2 6
Primary current(A) Secondary current(mA) Load resistance(Ω) Primary Turns(T)
1(30) 6 560 1/2
1(60) 2.5/3.3/5.8/6 400/720/3k/6k 1/2
1(80) 4/5.8 1k/3k 1/2
2(60) 3.3/4.3/6 720/900/560 1/2
2(200) 5 1k 1/2

Special Features


  • PT and CT are combined working together in this modular. It doesn’t just guarantee a better accurate measurement but also keep it contious working even as the Neutral Line drops

  • It’s with DC immunity and also different output turn ratio is realizable

  • Small in size to save space, and it can meet different installation size requirements

  • It’s very flexible in mounting size and it can be used together with primary Electrical brush line terminal

GJD-KXR-3H

Dimensions in (mm)


A B C D E F G H J K M
97 11.5 15.5 24 33.5 3 5 5 1 4.2 90
97 11.5 15.5 24 31 3 5 5 1 4.2 90
Primary current(A) Secondary current(mA)    Load resistance(Ω) AccuracyΩ
1.5(6) 1.5/2.5/5/7.5/10 ≤40 0.05/0.1
1.5(12)  1.5/2.5/5/7.5/10 ≤40 0.05/0.1
1(10) 2.5/5 ≤40 0.05/0.1
0.3(1.2) 0.3/5 ≤40 0.05/0.1
5(10) 2.5/5/10 ≤40 0.05/0.1

Special features


  • It can be fixed on the electrical meter bottom directly. It can be made as three phase 4 wires or three phase 3 wires

  • Nice appearance, fire-retardant case and epoxy resin encapsulated

  • High accuracy, Professional equipment adjustment, good consistency and strong interchangeability

GJD-KXR-004

Dimensions in (mm)


A B C D E F G H J K M
35.2 36.8 89 98 13.5 3 88 6 1 4.2 6.5
Primary current(A) Secondary current(mA) Load resistance(Ω) Accuracy
1.5(6) 1.5/2.5/5/7.5/10 ≤40 0.05/0.1
1.5(12) 1.5/2.5/5/7.5/10 ≤40 0.05/0.1
1(10) 2.5/5 ≤40 0.05/0.1
0.3(1.2) 0.3/5 ≤40 0.05/0.1
5(10) 2.5/5/10 ≤40 0.05/0.1

Special features


  • It can be fixed on the electrical meter bottom directly. It can be made as three phase 4 wires or three phase 3 wires

  • Nice appearance, fire-retardant case and epoxy resin encapsulated

  • High accuracy, Professional equipment adjustment, good consistency and strong interchangeability

  • It has short circuit or open circuit detection function. It is only used in Terminal specialization meter.

GJD-KXR-057 series

Dimensions in (mm)


B C D E F G H J M N
36.5 96 104 18.2 3 60 4.2 3.5 4 32
44 96 104 22 3 60 4.2 3.5 4 32
Primary current(A) Secondary current(mA) Load resistance(Ω) Accuracy
1.5(6) 1.5/2.5/5/7.5/10 ≤40 0.05/0.1
1.5(12) 1.5/2.5/5/7.5/10 ≤40 0.05/0.1
1.5(10) 2.5/5 ≤40 0.05/0.1
0.3(1.2) 0.3/5 ≤40 0.05/0.1
5(10) 2.5/5/10 ≤40 0.05/0.1

Special features


  • It can be fixed on the electrical meter bottom directly. It can be made as three phase 4 wires or three phase 3 wires

  • It has short circuit or open circuit detection function. It is only used in Terminal specialization meter.

  • Nice appearance, fire-retardant case and epoxy resin encapsulated

  • High accuracy, Professional equipment adjustment, good consistency and strong interchangeability