Single Phase Current Transformers Series
Customized CTs are available upon request
Features Of Single Phase Current Transformers
Excellent linearity & precision
Steady phase shift & no satuation in DC factor for DC immunity CTs
Steady from the external magnetic field
Possible to adopt the permanent magnetic immunity
High potential voltage from 2.5Kv to 4Kv/minute
ROHS compliant
Excellent stability % sensitivity in miniature current
Super accuracy for 0.1 &0.2 class meter grade
Applications
Precision Electronic Energy Meters, Water Meters etc
Smart Grid Application
In home display (home energy management system)
Multiple Models To Choose
GJD-KXR-041 series
Dimensions in (mm)
A | B | C | D | E | F | G | J | K |
25.7 | 28.5 | 21 | 7.5 | 5.2 | 15 | 2 | 3.5 | 26 |
29.5 | 29 | 21 | 8 | 6.2 | 15 | 2.5 | 3.5 | 26 |
Primary current(A) | Secondary current(mA) | Load resistance(Ω) | Accuracy |
5(60) | 2.5/5 | ≤20 | 0.1/0.2 |
10(60) | 5/10 | ≤20 | 0.1/0.2 |
5(80) | 2.5/5 | ≤20 | 0.1/0.2 |
20(80) | 10/20 | ≤20 | 0.1/0.2 |
10(100 | 5/10 | ≤20 | 0.1/0.2 |
Special Features
Linearity output current and there are multiple accuracy class to choose
It’s with DC immunity
Small in size to save space, and it can meet different installation size requirements
Nice appearance, fire-retardant case and wrapped with heat shrink tube
GJD-KXR-093 series
Dimensions in (mm)
A | B | C | D | E | F | G | H | J | K | M |
23.5 | 20/21 | 10.5 | 28 | 7 | 11 | 5.2 | 4 | 3.5 | 26 | 12.2/11.2 |
22.5 | 20/21 | 10.5 | 28 | 7 | 11 | 5.2 | 4 | 3.5 | 26 | 12.2/11.2 |
Primary current(A) | Secondary current(mA) | Load resistance(Ω) | Accuracy |
5(60) | 2.5/5 | ≤20 | 0.1/0.2 |
10(60) | 5/10 | ≤20 | 0.1/0.2 |
10(100) | 5/10 | ≤20 | 0.1/0.2 |
Special Features
Linearity output current and there are multiple accuracy class to choose
It can be connected with Meter terminal directly
Nice appearance, fire-retardant case and epoxy resin encapsulated
Small in size to save space, and it can meet different installation size requirements
GJD-KXR-177 series
Dimensions in (mm)
A | B | C | D | E | F | G | H | J |
7 | 21 | 30 | 11 | 5.2 | 11 | 2 | 22.5 | 3.5 |
7 | 21 | 30 | 11 | 5.2 | 11 | 2 | 24.2 | 3.5 |
Primary current(A) | Secondary current(mA) | Load resistance(Ω) | Accuracy |
5(60) | 2.5/5 | ≤20 | 0.1/0.2 |
10(60) | 5/10 | ≤20 | 0.1/0.2 |
10(100) | 5/10 | ≤20 | 0.1/0.2 |
Special Features
Linearity output current and there are multiple accuracy class to choose
It can be connected with Meter terminal directly
Nice appearance, fire-retardant case and epoxy resin encapsulated
Small in size to save space, and it can meet different installation size requirements
GJD-KDT-050 series
Dimensions in (mm)
A | B | C | D | E | F | G |
30 | 19 | 28 | 29.3 | 8 | 2 | 3.5 |
30 | 19 | 28 | 29.3 | 8 | 1.5 | 3.5 |
Primary current(A) | Secondary current(mA) | Load resistance(Ω) | Accuracy |
5(60) | 2/2.5/5 | ≤20 | 0.1/0.2 |
10(60) | 4/5/10 | ≤20 | 0.1/0.2 |
10(100) | 4/5/10 | ≤20 | 0.1/0.2 |
Special Features
Linearity output current and there are multiple accuracy class to choose
It’s with DC immunity
Nice appearance, fire-retardant case and epoxy resin encapsulated
Small in size to save space, and it can meet different installation size requirements